Specifications |
Control Pressure kpa (kgf/cm?, psi) | 500.14 ~ 9.81 (5.1 ~ 0.1, 72.54 ~ 1.42) |
Current value (mA) | 50 ~ 850 |
Internal resistance (?) | 5.1 |
Description Underdrive brake control solenoid valve(UD/B_VFS) is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure to the underdrive brake. ...
Circuit Diagram ...
Inspection 1. Ignition "OFF". 2. Disconnect the intake actuator connector. 3. Verify that the actuator operates to the recirculation position when connecting 12V to the terminal 3 and grounding terminal 7. 4. Verify that the intake actuator operates to the fresh position when connecting in the reverse. ...
Replacement 1. Remove the rear wheel & tire. Tightening torque: 88.3 ~ 107.9N.m(9.0 ~ 11.0kgf.m, 65.1 ~ 79.6lb-ft) Be careful not to damage the hub bolts when removing the rear wheel & tire. 2. Remove the rear lower arm. (Refer to lower arm) 3. Remove the rear shock absorber. (Refer ...