Kia Optima Hybrid: Air Conditioning System / Evaporator Temperature Sensor Repair procedures

Inspection
1.
Ignition "OFF"
2.
Disconnect evaporator temperature sensor.
3.
Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor.

Specification
Evaporator core
temperature[°C(°F)]
Resistance[K?]
-10 / (14)
43.35
0 / (32)
27.62
10 / (50)
18.07
20 / (68)
12.11
30 / (86)
8.3
40 / (104)
5.81

Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Loosen the mounting screw and then remove the crash pad lower cover (A).

3.
Remove the evaporator temperature sensor (A), by pulling it after rotating 90° in a counterclockwise direction.

4.
Installation is the reverse order of removal.
Evaporator Temperature Sensor Description and Operation

Description The evaporator temperature sensor will detect the evaporator core temperature and interrupt compressor relay power in order to prevent evaporator freezing by excessive cooling ...

A/C Pressure Transducer Components and Components Location

Component Location ...

Other information:

Kia Optima Hybrid (TF HEV) 2016-2020 Service Manual: Heater & A/C Control Unit(Dual) Components and Components Location


Components (1) Control Panel (Dual A/C & Heater Controller - A) Connector pin function (1) ConnectorPIN NO.FunctionConnectorPIN NO.FunctionConnector (A)1ILL+(TAIL)Connector (A)29ECV (+)2SENSOR REF (+5V)30ECV (-) (GND)3HAZARD SIGNAL31PHOTO SENSOR (-) -LEFT4ACC32PHOTO SENSOR (-) -RIGHT5MODE ACT''R ...

Kia Optima Hybrid (TF HEV) 2016-2020 Service Manual: Oil Pressure Switch Repair procedures


Inspection 1. Check the continuity between the terminal and the body with an ohmmeter. If there is no continuity, replace the oil pressure switch. 2. Check the continuity between the terminal and the body when the fine wire is pushed. If there is continuity even when the fine wire is pushed, replace ...

© 2025 Copyright www.koptimatfhev.com