Inspection |
1. |
Ignition "OFF" |
2. |
Disconnect evaporator temperature sensor. |
3. |
Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor. Specification
|
Replacement |
1. |
Disconnect the negative (-) battery terminal. |
2. |
Loosen the mounting screw and then remove the crash pad lower cover (A). |
3. |
Remove the evaporator temperature sensor (A), by pulling it after rotating 90° in a counterclockwise direction. |
4. |
Installation is the reverse order of removal. |
Description The evaporator temperature sensor will detect the evaporator core temperature and interrupt compressor relay power in order to prevent evaporator freezing by excessive cooling ...
Component Location ...
Specification Smart Key Unit ItemsSpecificationRated voltageDC 12VOperating voltageDC 9 ~ 16VOperating temperature-30°C ~ 75°C (-22°F ~ 167°F)LoadMax. 2.9mA (When welcome light off)(When welcome light function ON, increase 2mA - 60days average) RF Receiver ItemsSpecificationFrequency315 MHzAntenna ...
Inspection 1. Check-points upon head lamp failure (HID) (1) Check the battery voltage. (Low beam will be on when the battery voltage above 9V.) (2) Check the fuse and relay. (3) Check the polarity of ballast. (If the polarity are changed, low beam doesn''t lighten) (4) Check the bulb connector securely. ...