Description |
Replacement 1. Remove the condenser, and then remove the bottom cap (B) with L wrench (A) from the condenser. Tightening torque : 20~25N.m (2.0~2.5kgf.m, 14.5~18.2lb-ft) 2. Remove the desiccant (A) from ...
Inspection 1. Ignition "OFF" 2. Disconnect evaporator temperature sensor. 3. Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor. Specification Evaporator ...
Inspection 1. Press the MODE switch more then 4 times within 2 seconds while pressing the OFF switch. DisplayFail description00Normal50Cluster ion generator fault * Diagnostic procedure refer to DTC code. Replacement 1. Disconnect the negative (-) battery terminal. 2. Remove the crash pad. (Refer to ...
Inspection 1. Ignition "ON" 2. Manually operate the control switch and measure the voltage of blower motor. 3. Select the control switch to raise voltage until high speed. BLOWER speedManual VoltageAuto Voltage13.4Auto Low(4.5V)24.64.5~5.535.95.6~6.747.26.8~7.758.37.8~8.969.59.0~10.1711.310.2~11.38B+? ...