Inspection |
1. |
Turn ignition switch OFF. |
2. |
Remove the air duct (A).
|
3. |
Remove the air cleaner assembly.
|
4. |
Remove the solenoid valve connector (A). |
5. |
Measure resistance between signal terminal and ground terminal. |
6. |
Check that the resistance is within the specification. |
Removal |
Replacing an on/off solenoid valve (SS-A, SS-B) does not
require additional hydraulic pressure adjustment; however, the hydraulic
pressure will need to be adjusted after replacing the VFS solenoid
valve. If replacing the VFS solenoid valve; also replace the valve body
assembly.
(Refer to Hydraulic System - "Valve Body") |
Circuit Diagram ...
Description Line pressure control solenoid valve is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure to the line pressure. ...
Specifications ItemsSpecificationsRated voltageDC 12VOperating voltageDC 9 ~ 16VOperating temperature-22°F~176°F(-30°C~ 80°C)Dark currentBCM & Receiver : 5.5mABCM : 4mA ...
Specifications Type: Hall effect sensor Operation condition (°C)°F((-)40 ~ 150)) -104 ~ 302Air gap(mm)in.(0.25 ~ 1.9)0.00984 ~ 0.0748Output voltageHigh1.18 ~ 1.68Low0.59 ~ 0.84 ...