Inspection |
1. |
Turn ignition switch OFF. |
2. |
Remove the air duct (A).
|
3. |
Remove the air cleaner assembly.
|
4. |
Remove the solenoid valve connector (A). |
5. |
Measure resistance between signal terminal and ground terminal. |
6. |
Check that the resistance is within the specification. |
Removal |
Replacing an on/off solenoid valve (SS-A, SS-B) does not
require additional hydraulic pressure adjustment; however, the hydraulic
pressure will need to be adjusted after replacing the VFS solenoid
valve. If replacing the VFS solenoid valve; also replace the valve body
assembly.
(Refer to Hydraulic System - "Valve Body") |
Circuit Diagram ...
Description Line pressure control solenoid valve is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure to the line pressure. ...
Personal Protective Equipment NameIllustrationDescriptionInsulation gloveUsed when inspecting or working on the high voltage components[Insulation performance : 1000V / 300A or above]Insulation shoesUsed when inspecting or working on the high voltage componentsInsulation clothesInsulation helmetSafety ...
Specifications PumpPumping capacityAbout 6.46cc per one revolutionTypeInternal gearMotorType Brushless DC motor (3 phases)Torque Rated 1.5 N.mSpeed range100~2,500 rpm ...