Kia Optima Hybrid: Charging System / Repair procedures

On-vehicle Inspection
   
Check that the auxiliary 12V battery cables are connected to the correct terminals.
Disconnect the auxiliary 12V battery cables when the battery is given a quick charge.
Never disconnect the auxiliary 12V battery while the engine is running.
Check The Auxiliary 12V Battery Terminals And Fuses
1.
Check that the auxiliary 12V battery terminals are not loose or corroded.
2.
Check the fuses for continuity.
Check Discharge Warning Light Circuit
1.
Warm up the engine and then turn it off.
2.
Turn off all accessories.
3.
Turn the ignition switch "ON". Check that the discharge warning light is lit.
4.
Start the engine and Check that the light goes off.
If the light does not go off as specified, then refer to the LDC diagnostics section for further diagnosis of auxiliary 12V battery charging system problem.
Charging System

...

Auxiliary 12V Battery Components and Components Location

Components 1. Battery tray2. Auxiliary 12V Battery3. Battery upper bracket ...

Other information:

Kia Optima Hybrid (TF HEV) 2016-2020 Service Manual: High Voltage Shut-off Procedures


High Voltage Shut-off Procedures     Be sure to read and follow the “General Safety Information and Caution” before doing any work related with the high voltage system. Failure to follow the safety instructions may result in serious electrical injuries.     • High voltage components: ...

Kia Optima Hybrid (TF HEV) 2016-2020 Service Manual: Blower Motor Repair procedures


Inspection 1. Connect the battery voltage and check the blower motor rotation. 2. If the blower motor voltage is not operated well, substitute with a known-good blower motor and check for proper operation. 3. If the problem is corrected, replace the blower motor. Replacement 1. Disconnect the negative ...