Personal Protective Equipment |
Name | Illustration | Description |
Insulation glove | Used when inspecting or working on the high voltage components [Insulation performance : 1000V / 300A or above] | |
Insulation shoes | Used when inspecting or working on the high voltage components | |
Insulation clothes | ||
Insulation helmet | ||
Safety glasses | Used in the case below • During Removal & installation or inspection of the high voltage battery terminals or wiring, which spark might happen. • During working on the high voltage battery pack assembly. | |
Face shield | ||
Insulation mat | Putting the removed high voltage components on the insulation mat to prevent safety accidents. | |
Insulation sheet | Covering
the high voltage components with insulation sheet to prevent people who
don’t wear the personal protective equipment from safety accidents. |
Specification Air Conditioner ItemSpecificationCompressorTypeESC33iOil type & CapacityPOE OIL 3.8~4.5oz. (115~135cc)Motor typeBLDCDisplacement33cc/revCondenserHeat rejection14,000 ± 5% kcal/hrA/C ...
Troubleshooting Problem Symptoms Table Before replacing or repairing air conditioning components, first determine if the malfunction is due to the refrigerant charge, air flow or compressor. Use the table ...
Replacement 1. Disconnect the battery negative cable from the battery and then wait for at least 30 seconds. 2. Turn the steering wheel so that the front wheels can face straight ahead. 3. Push the pin (A) and then disconnect the airbag module from the steering wheel. 4. Disconnect the airbag module ...
Removal 1. If the compressor is marginally operable, run the engine, and let the air conditioning work for a few minutes, then shut the engine off. 2. Shut off the high voltage circuit.(Refer to Hybrid Control System - High Voltage Shutoff) 3. Recover the refrigerant with a recovery/charging station. ...