Inspection |
1. |
After disconnecting the vapor hose from the PCV valve, remove the PCV valve. |
2. |
Reconnect the PCV valve to the vapor hose. |
3. |
Run the engine at idle, then put a finger over the open end
of the PCV valve and make sure that intake manifold vacuum can be felt.
|
4. |
If the vacuum is not felt inspect PCV operation, if operating correctly clean or replace the vapor hose. |
Schematic Diagram ...
Operation Principle ...
Removal • Be sure to read and follow the “General Safety Information and Caution” before doing any work related with the high voltage system. Failure to follow the safety instructions may result in serious electrical injuries. • Be sure to shut off the high voltage circuit according ...
Specification HO2S [Bank 1/Sensor 1] (Linear type) ItemSpecificationHeater Resistance (?)2.5 ~ 4.0 [20°C(68°F)] HO2S [Bank 1/Sensor 2] (Binary type) A/F Ratio (?)Output Voltage(V)RICHApprox. 0.92LEANApprox. 0.04 ItemSpecificationHeater Resistance (?)3.3 ~ 4.1?[21°C(69.8°F)] ...