Replacement |
1. |
Discharge refrigerant from refrigeration system. |
2. |
Replace faulty tube or hose.
|
3. |
Tighten joint of bolt or nut to specified torque.
|
4. |
Evacuate air in refrigeration system and charge system with refrigerant.
|
5. |
Inspect for leakage of refrigerant.
Using a gas leak detector, check for leakage of refrigerant. |
6. |
Inspect A/C operation. |
Component Location ...
Troubleshooting Fault codeFail descriptionRemedy60Compressor CAN signal fault1. Check HV, LV connector connection. 2. Check LV connector pin condition. 3. Check vehicle inverter fuse condition. 4. ...
High Voltage Shut-off Procedures Be sure to read and follow the “General Safety Information and Caution” before doing any work related with the high voltage system. Failure to follow the safety instructions may result in serious electrical injuries. • High voltage components: ...
Inspection 1. Connect the battery voltage and check the heater hose pump motor rotation. 1. +2. - 2. If the heater hose pump voltage is not operated well, substitute with a known-good heater hose pump and check for proper operation. 3. If the problem is corrected, replace the heater hose pump. Replacement ...