Inspection Lighting Switch Inspection With the multifunction switch in each position, make sure that continuity exists between the terminals below. If continuity is not as specified, replace the multi-function ...
Component Location 1. Horn switch2. Horn relay (Engine room compartment)3. Horn (Low)4. Clock spring5. Horn (High) ...
Specification ItemSpecificationCoil Resistance (?)6.9 ~ 7.9 [20°C(68°F)] ...
Inspection 1. It will be able to diagnose defects of hazard switch with GDS quickly. GDS can operates actuator forcefully, input/output value monitoring and self diagnosis. 2. Select model and "BCM". 3. Select the "SJB" to check. 4. Select "Current data", if you will check current data of hazard switch. ...