Inspection |
1. |
Ignition "OFF" |
2. |
Disconnect ambient temperature sensor. |
3. |
Check the resistance of ambient temperature sensor between
terminals 1 and 2 whether it is changed by changing of the ambient
temperature.
Specification
|
4. |
If the measured resistance is not specification, substitute
with a known-good ambient temperature sensor and check for proper
operation. |
5. |
If the problem is corrected, replace the ambient temperature sensor. |
Replacement |
1. |
Disconnect the negative (-) battery terminal. |
2. |
Loosen the mounting bolts and then remove the under cover (A). |
3. |
Disconnect the connector and then remove the ambient temperature sensor (A). |
4. |
Installation is the reverse order of removal. |
Description 1. The ambient temperature sensor is located at the front of the condenser and detects ambient air temperature. It is a negative type thermistor; resistance will increase with lower temperature, ...
Component Location ...
High Voltage Shut-off Procedures Be sure to read and follow the “General Safety Information and Caution” before doing any work related with the high voltage system. Failure to follow the safety instructions may result in serious electrical injuries. • High voltage components: ...
Components 1. Front door trim2. Front door quadrant inner cover3. Front door belt inside weatherstrip4. Front door module5. Front door panel6. Front door side impact pad7. Front door belt outer weatherstrip8. Front door upper opening weatherstrip9. Front door frame moulding10. Front door window glass ...